Permanent and Dynamic Behaviours of Self-excited Induction Generator In balanced mode
Abstract
Due to its various advantages over the synchronous generator, the induction machine (IM) can be used as a generator in remote and rural areas. It be haves as a generator when its rotor is driven above its asynchronous speed. The required reactive power is provided by a local capacitors bank connected to the stator of the IM. Both permanent and transient modes of the self excited induction generator (SEIG) are studied. In both cases (loaded and no-loaded), the evolution of the output voltage for different values of the excitation capacitor and speed is presented. We analyze also, the influence of the capacitors and speed values on start-up of the SEIG. A comparison between laboratory tests and simulation results is done, that demonstrate the effectiveness of the proposed model.